TruBaby® X Lite is incredibly lifelike with the appearance, weight, size and movement of a 5-month-old infant. Our
pediatric clinical skills training model is ideal for nurses practicing Directly Observed Practical Skills (DOPS),
Pediatric Basic Life Support (PBLS), and more.
Versatile | Realistic | Durable
The TruBaby X range is a realistic pediatric manikin designed to standardise infant skills such as airway
management, IV cannulation, intraosseous infusion and more, ensuring relevancy across a number of clinical education
programmes. This range replicates the appearance, weight, size, and movement of a 50th percentile 5-month-old
infant, enabling credible, repeatable simulation that supports competency development and consistent assessment
outcomes.
Complete Training Coverage
Purpose-built to support core paediatric vascular access workflows, including:
Airway management
Peripheral IV cannulation (arms, hands & feet)
CPR
Intramuscular (IM) injection
Urethral catherisatio
Intraosseous (IO) infusion
Ideal for Busy Classrooms
This manikin facilitates training multiple skills simultaneously such as bilateral chest drain insertion and
complete chest needle decompression training. Ideal for simulating a busy emergency department or clinical
setting.
Durability & Replacement Consumables
Optimised for medical training manikins sessions in busy education environments:
Airway - 80,000+ intubation cycles
IO Infusion - Each IO insert withstands up to 5 procedures
IV Cannulation - 250+ needle penetrations per IV and IM injection site
Urethral Catheterisation - 100+ insertions
Lumbar Puncture - 100+ insertions
Needle Decompressions - 150+ needle insertions
Chest drain - 150+ needle insertions or 1 use seldinger technique
Cost-Effective Modular Design
The unit is ready for use in under 5 minutes, quick and easy replacement of inserts to maintain training
quality and minimise downtime.
Package Contents:
1 left & 1 right TruBaby X Arm (TBARML01/TBARMR01)
1 left & 1 right TruBaby X Leg (TBLEGL01/TBLEGR01)
1 left & 1 right TruBaby X IO inserts (TBIO20)
1 TruBaby X female genitalia insert (TBUI01F)
Download:
Additional package contents:
1 TruBaby X Lite carrier case
100ml bottle of TruCorp lubrication (TL001)
250ml bottle of artificial blood concentrate (CVB250)
1 syringe with yellow and white tubing for fluid insertion/removal throughout model
4 left & 4 right TruBaby X Lite IO inserts (TBIO20)
1 TruBaby X Lite male genitalia insert (TBUI01M)
GTSimulators by Global Technologies TruCorp Authorized Dealer
Hover to play
Airway Management
Practise advanced infant airway procedures including bag-mask ventilation, oral and nasal intubation.
Tested for 80,000+ intubations.
Hover to play
CPR
Practise high-quality infant CPR with TruBaby X, featuring realistic chest anatomy, full compression
depth
with recoil, and lifelike ventilation response for improved practitioner confidence.
Hover to play
Peripheral Venous Cannulation
TruBaby X enables realistic pediatric IV cannulation training in the arm, hand, and foot, with
accurate
vein anatomy for multiple insertion sites.
Blood flow mode provides lifelike flashback for fluid withdrawal and administration.
Hover to play
Urethral Catheterization
TruBaby X supports realistic infant urethral catheterization training with accurate anatomy and
interchangeable male and female genitalia.
Learners can insert an 8F catheter into the bladder with fluid flow confirmation upon successful
placement.
Hover to play
IO Tibia
TruBaby X enables realistic infant intraosseous tibial infusion training with clear anatomical
landmarks, including the tibial tuberosity and patella for accurate site identification.
Learners experience true-to-life resistance during needle insertion, with pre-filled inserts
supporting
realistic fluid access practice.
The AirSim® airway has been designed using CT DICOM data from real patients, to provide trainees
with a lifelike intubation training solution. Our airway and softer skin has been rigorously
tested to withstand over 80,000 intubation cycles without failure. This ensures greater tactile
accuracy, helping users develop critical airway management skills with confidence.
IV Cannulation (hands, arms, and feet): up to 300+ needle penetrations per single
arm, and
up to 250+ needle penetrations per foot (non-ultrasound inserts)
IO Tibia: Single use per IO insert
Urethral catheterization: 100+ catheterization procedures per genitalia insert
All consumables are quick and easy to interchange so there is no disruption to
teaching
time
We recommend TruCorp’s lubrication for best practice, but alternatives can be used provided
they
are water-soluble lubricants. Please do not use silicone-based products as they will degrade
the
materials.
No, this training manikin is delivered with all parts attached. You will simply need to fill the
fluid system. Please refer to the user manual for instructions on how to fill the fluid system.
For airway management training, generously spray the oral/nasal passages and equipment with the
lubrication provided.
Please contact us and provide the serial number (found under the neck skin of the manikin) and
an image/video of the issue. If it meets the warranty conditions TruCorp will repair free of
charge. If the warranty has expired, our sales team will provide a quote for repair.
Please store the manikin in clean, dry conditions away from heat and direct sunlight. Avoid
contact with metals, solvents, oils or greases and strong detergents. When the product is not in
use please store in the black carrier case provided.
Thoroughly wash the AirSim® airway in warm water. Please use warm soapy water or similar
until
all
visible foreign matter and residue is removed.
Mild detergents or enzymatic cleaning agents may be used on the airway at the proper
dilution.
The
detergent must not contain skin or mucous membrane irritants.
Please do not use any of the following when cleaning the AirSim® product range:
Germicides, disinfectants, or chemical agents such as glutaraldehyde (e.g. Cidex®)
Ethylene oxide, phenol-based cleaners or iodine-containing cleaners
In response to the recent COVID-19 pandemic, we recommend this additional step to ensure the
product
is fully sanitized:
Generously spray alcohol spray or gel (minimum 75% alcohol) and wipe off. Repeat 3-4 times
to
fully
disinfect the product. This can be done on the silicone skin and the latex airway.
We recommend a frequent deep clean of the internal fluid systems to prevent mould and fungal
build-up. A sterilizing product such as Milton Sterilizing Fluid is sufficient.
• Item # TBL10001X
• By TruCorp Ltd — A trusted GT Partner.
• 2-Year Warranty provided by the manufacturer.
Description:
TruBaby® X Lite Pediatric Basic Skills Trainer
TruBaby® X Lite is incredibly lifelike with the appearance, weight, size and movement of a 5-month-old infant. Our
pediatric clinical skills training model is ideal for nurses practicing Directly Observed Practical Skills (DOPS),
Pediatric Basic Life Support (PBLS), and more.
Versatile | Realistic | Durable
The TruBaby X range is a realistic pediatric manikin designed to standardise infant skills such as airway
management, IV cannulation, intraosseous infusion and more, ensuring relevancy across a number of clinical education
programmes. This range replicates the appearance, weight, size, and movement of a 50th percentile 5-month-old
infant, enabling credible, repeatable simulation that supports competency development and consistent assessment
outcomes.
Complete Training Coverage
Purpose-built to support core paediatric vascular access workflows, including:
Airway management
Peripheral IV cannulation (arms, hands & feet)
CPR
Intramuscular (IM) injection
Urethral catherisatio
Intraosseous (IO) infusion
Ideal for Busy Classrooms
This manikin facilitates training multiple skills simultaneously such as bilateral chest drain insertion and
complete chest needle decompression training. Ideal for simulating a busy emergency department or clinical
setting.
Durability & Replacement Consumables
Optimised for medical training manikins sessions in busy education environments:
Airway - 80,000+ intubation cycles
IO Infusion - Each IO insert withstands up to 5 procedures
IV Cannulation - 250+ needle penetrations per IV and IM injection site
Urethral Catheterisation - 100+ insertions
Lumbar Puncture - 100+ insertions
Needle Decompressions - 150+ needle insertions
Chest drain - 150+ needle insertions or 1 use seldinger technique
Cost-Effective Modular Design
The unit is ready for use in under 5 minutes, quick and easy replacement of inserts to maintain training
quality and minimise downtime.
Package Contents:
1 left & 1 right TruBaby X Arm (TBARML01/TBARMR01)
1 left & 1 right TruBaby X Leg (TBLEGL01/TBLEGR01)
1 left & 1 right TruBaby X IO inserts (TBIO20)
1 TruBaby X female genitalia insert (TBUI01F)
Download:
Additional package contents:
1 TruBaby X Lite carrier case
100ml bottle of TruCorp lubrication (TL001)
250ml bottle of artificial blood concentrate (CVB250)
1 syringe with yellow and white tubing for fluid insertion/removal throughout model
4 left & 4 right TruBaby X Lite IO inserts (TBIO20)
1 TruBaby X Lite male genitalia insert (TBUI01M)
GTSimulators by Global Technologies TruCorp Authorized Dealer
Hover to play
Airway Management
Practise advanced infant airway procedures including bag-mask ventilation, oral and nasal intubation.
Tested for 80,000+ intubations.
Hover to play
CPR
Practise high-quality infant CPR with TruBaby X, featuring realistic chest anatomy, full compression
depth
with recoil, and lifelike ventilation response for improved practitioner confidence.
Hover to play
Peripheral Venous Cannulation
TruBaby X enables realistic pediatric IV cannulation training in the arm, hand, and foot, with
accurate
vein anatomy for multiple insertion sites.
Blood flow mode provides lifelike flashback for fluid withdrawal and administration.
Hover to play
Urethral Catheterization
TruBaby X supports realistic infant urethral catheterization training with accurate anatomy and
interchangeable male and female genitalia.
Learners can insert an 8F catheter into the bladder with fluid flow confirmation upon successful
placement.
Hover to play
IO Tibia
TruBaby X enables realistic infant intraosseous tibial infusion training with clear anatomical
landmarks, including the tibial tuberosity and patella for accurate site identification.
Learners experience true-to-life resistance during needle insertion, with pre-filled inserts
supporting
realistic fluid access practice.
The AirSim® airway has been designed using CT DICOM data from real patients, to provide trainees
with a lifelike intubation training solution. Our airway and softer skin has been rigorously
tested to withstand over 80,000 intubation cycles without failure. This ensures greater tactile
accuracy, helping users develop critical airway management skills with confidence.
IV Cannulation (hands, arms, and feet): up to 300+ needle penetrations per single
arm, and
up to 250+ needle penetrations per foot (non-ultrasound inserts)
IO Tibia: Single use per IO insert
Urethral catheterization: 100+ catheterization procedures per genitalia insert
All consumables are quick and easy to interchange so there is no disruption to
teaching
time
We recommend TruCorp’s lubrication for best practice, but alternatives can be used provided
they
are water-soluble lubricants. Please do not use silicone-based products as they will degrade
the
materials.
No, this training manikin is delivered with all parts attached. You will simply need to fill the
fluid system. Please refer to the user manual for instructions on how to fill the fluid system.
For airway management training, generously spray the oral/nasal passages and equipment with the
lubrication provided.
Please contact us and provide the serial number (found under the neck skin of the manikin) and
an image/video of the issue. If it meets the warranty conditions TruCorp will repair free of
charge. If the warranty has expired, our sales team will provide a quote for repair.
Please store the manikin in clean, dry conditions away from heat and direct sunlight. Avoid
contact with metals, solvents, oils or greases and strong detergents. When the product is not in
use please store in the black carrier case provided.
Thoroughly wash the AirSim® airway in warm water. Please use warm soapy water or similar
until
all
visible foreign matter and residue is removed.
Mild detergents or enzymatic cleaning agents may be used on the airway at the proper
dilution.
The
detergent must not contain skin or mucous membrane irritants.
Please do not use any of the following when cleaning the AirSim® product range:
Germicides, disinfectants, or chemical agents such as glutaraldehyde (e.g. Cidex®)
Ethylene oxide, phenol-based cleaners or iodine-containing cleaners
In response to the recent COVID-19 pandemic, we recommend this additional step to ensure the
product
is fully sanitized:
Generously spray alcohol spray or gel (minimum 75% alcohol) and wipe off. Repeat 3-4 times
to
fully
disinfect the product. This can be done on the silicone skin and the latex airway.
We recommend a frequent deep clean of the internal fluid systems to prevent mould and fungal
build-up. A sterilizing product such as Milton Sterilizing Fluid is sufficient.